PRIMA LUX is an high-tech diode laser designed for the dental practice that wants to offer to its patients non-invasive, targeted and effective dental and aesthetic treatments,with a great prognostic predictability. The intrinsic properties of the diode light radiation, the anti-inflammatory and decontamination actions, the bio-stimulating effect, the analgesic and hemostatic capacity – are fulfilled by a large number of pre-set dental programs and dermatological/aesthetic applications supplied with clinically validated operating protocols. Equipped with specific handpieces for surgery, therapy and aesthetic treatments, PRIMA LUX stands out as an innovative, reliable and easy to use instrument offering highly efficient performances by putting all the clinical benefits of laser therapy at service of smile care and facial beauty.
DESIGN
Compact shape, modern design and easy installation are the features that make PRIMA LUX perfectly fitting to any dentist office and easily transportable from a dental surgery to another.
LARGE DISPLAY
A wide alphanumeric LCD on the main screen allows to distinctly read all the parameters visualized and permit to control the main settings at any moment of the clinical practice.
HANDPIECES
PRIMA LUXis equipped with ergonomic handpieces which allow firm gripping and easy handling. Optical fibers conveying laser radiations are housed in though sheathes and supported by a thin stem that enables the practitioner to move freely.
UPGRADABILITY
Thanks to a special internal microprocessor, PRIMA LUX turns out to be an easily updatable device: new functions and treatments can be added. The updating is easy and makes PRIMA LUX an unsurpassed instrument always up-to-date with the latest clinical applications.
SAFETY
Innovative elements make our PRIMA LUX one of the safest laser systems in the market sale also for hospital use. Some of them are, for instance, the protective glasses, the interlock system which automatically stops the laser radiation in case of access doors opening, the light signal to be placed outside the dental surgery during laser emission.
NO TOUCH SYSTEM
the doctor can set up all the parameters and interact with the device only using his feet, thus having his hands free of moving in the operating scope.
CLINICAL ADVANTAGES
The instrument of choice in periodontics for its excellent antibacterial action in the treatment of infected pockets and of perim plantitis, PRIMA LUX is an equally irreplaceable aid in endodontics in the treatment of root canals, of dentinal hypersensitivity and in dentin vitrification.
In surgery, its special ability to vaporize muco-gingival flaps and its high coagulating power without tissue carbonization or necrotizing effects, make it an effective and decisive instrument in many applications including frenectomy, fibroids excision, herpes, mouth ulcers, fistulas, vascular lesions, abscesses, epulis treatments. The anti-inflammatory and analgesic properties of the diode laser, in addition, involve a drastic reduction in the use of anaesthetic and are critical in the traumatologic-analgesic field, especially in the treatment of myofascial pain syndrome, infection of the ATM, carpal tunnel and paresthesia.
Under the dermatological-aesthetic point of view, finally, the painless effectiveness and non-invasiveness of photodynamic therapy of PRIMA LUX are expressed in a large number of applications such as psoriasis, senile freckles, xanthelasma, folliculitis, keratosis, photorejuvenation, acne scars in addition to tooth whitening, whose specific protocol allows to avoid the risk of dentin sensitization that occurs,however, with the use of other instruments such as bleaching lamps.
THE TREATMENTS
All the set-up treatments provided by PRIMA LUX result from an accurate clinical validation and make reference to preeminent studies published on the most prestigious scientific journals. Among our personnel we can count on a skilled medical staff who thoroughly check that PRIMA LUXparameters are lined up with the above mentioned studies.
Component & Options:
Technical Features: | ||
Prima Lux Light | Prima Lux | |
Power supply | 100-240 V AC | 100-240 V AC |
Power frequency | 50-60 Hz | 50-60 Hz |
Input maximum power | 1,5 A AC | 1,5 A AC |
Output power | 12 V DC ; 4,17 A | 12 V DC ; 4,17 A |
Maximum current absorbed by the system | 2 A | 3 A |
Maximum laser power on working point | 3 W | 5 W |
Medical class | II B | II B |
Insulation class | I – type BF applied part | I – type BF applied part |
Laser class | IV | IV |
Dimensions | 24x28x8 cm | 24x28x8 cm |
Weight | 2kg approx. | 2kg approx. |
MAIN PARAMETERS | ||
Power | 0,1 W – 3,0 W | 0,1 W – 5,0 W |
Laser emission mode | Selectable: Continuous – 1000 Hz | Selectable: Continuous – 1000 Hz |
Duty Cycle | 50% | 50% |
Operating mode | Continuous – Timed min 1s, max 99s – 30 min. | Continuous – Timed min 1s, max 99s – 30 min. |
Emission power stability | ± 20% | ± 20% |
Wavelength | 808nm | 808nm |
Laser source power | 10W | 10W |